Reliability of intraoperative ultrasound in detecting tumor residual after brain diffuse glioma surgery: a systematic review and meta-analysis.

Details

Serval ID
serval:BIB_7358B1A998BF
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Reliability of intraoperative ultrasound in detecting tumor residual after brain diffuse glioma surgery: a systematic review and meta-analysis.
Journal
Neurosurgical review
Author(s)
Trevisi G., Barbone P., Treglia G., Mattoli M.V., Mangiola A.
ISSN
1437-2320 (Electronic)
ISSN-L
0344-5607
Publication state
Published
Issued date
10/2020
Peer-reviewed
Oui
Volume
43
Number
5
Pages
1221-1233
Language
english
Notes
Publication types: Journal Article ; Review
Publication Status: ppublish
Abstract
Intraoperative ultrasonography (iUS) is considered an accurate, safe, and cost-effective tool to estimate the extent of resection of both high-grade (HGG) and low-grade (DLGG) diffuse gliomas (DGs). However, it is currently missing an evidence-based assessment of iUS diagnostic accuracy in DGs surgery. The objective of review is to perform a systematic review and meta-analysis of the diagnostic performance of iUS in detecting tumor residue after DGs resection. A comprehensive literature search for studies published through October 2018 was performed according to PRISMA-DTA and STARD 2015 guidelines, using the following algorithm: ("ultrasound" OR "ultrasonography" OR "ultra-so*" OR "echo*" OR "eco*") AND ("brain" OR "nervous") AND ("tumor" OR "tumour" OR "lesion" OR "mass" OR "glio*" OR "GBM") AND ("surgery" OR "surgical" OR "microsurg*" OR "neurosurg*"). Pooled sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR-), and diagnostic odds ratio (DOR) of iUS in DGs were calculated. A subgroup analysis for HGGs and DLGGs was also conducted. Thirteen studies were included in the systematic review (665 DGs). Ten articles (409 DGs) were selected for the meta-analysis with the following results: sensitivity 72.2%, specificity 93.5%, LR- 0.29, LR+ 3, and DOR 9.67. Heterogeneity among studies was non-significant. Subgroup analysis demonstrates a better diagnostic performance of iUS for DLGGs compared with HGGs. iUS is an effective technique in assessing DGs resection. No significant differences are seen regarding iUS modality and transducer characteristics. Its diagnostic performance is higher in DLGGs than HGGs and could be worsened by previous treatments, surgical artifacts, and small tumor residue volumes.
Keywords
Diffuse glioma, Extent of resection, High-grade glioma, Intraoperative ultrasound, Low-grade glioma, Residual tumor
Pubmed
Web of science
Create date
16/08/2019 17:05
Last modification date
24/10/2020 5:21
Usage data