Valproate in status epilepticus: Correlation between loading dose, serum levels, and clinical response.
Details
Download: 35686387_BIB_729D01C11191.pdf (435.31 [Ko])
State: Public
Version: Final published version
License: CC BY-NC 4.0
State: Public
Version: Final published version
License: CC BY-NC 4.0
Serval ID
serval:BIB_729D01C11191
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Valproate in status epilepticus: Correlation between loading dose, serum levels, and clinical response.
Journal
European journal of neurology
ISSN
1468-1331 (Electronic)
ISSN-L
1351-5101
Publication state
Published
Issued date
09/2022
Peer-reviewed
Oui
Volume
29
Number
9
Pages
2607-2611
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Publication Status: ppublish
Abstract
Intravenous valproate (VPA) is an established treatment of status epilepticus (SE), but optimal loading dose was not fully assessed. We aimed at analyzing the correlation between VPA loading dose and subsequent plasma levels with clinical response in SE.
This was a retrospective study in one referral center of all consecutive VPA-naïve SE episodes treated with VPA between January 2013 and June 2019, in which total VPA trough plasma levels after intravenous loading dose were available. Response to VPA, defined as last antiseizure medication introduced before SE resolution (without the need for additional treatment), was correlated with VPA loading dose and trough level. Correlations were adjusted for other SE characteristics.
Among 128 SE episodes, 53 (41%) responded to VPA. Median VPA loading dose was 25.2 mg/kg (range, 7-58 mg/kg). Loading doses and total plasma levels were not associated with the probability of response or mortality. Correcting for other possible confounders (number of previously tried treatment, demographics, SE severity) did not alter these findings. Only 3.8% of SE episodes that responded to VPA received >30 mg/kg.
A high loading dose (>30 mg/kg) is not associated with a greater response rate in patients with SE. Therefore, it seems to bring little benefit. If confirmed in further studies, a dosage of 25-30 mg/kg appears adequate in SE.
This was a retrospective study in one referral center of all consecutive VPA-naïve SE episodes treated with VPA between January 2013 and June 2019, in which total VPA trough plasma levels after intravenous loading dose were available. Response to VPA, defined as last antiseizure medication introduced before SE resolution (without the need for additional treatment), was correlated with VPA loading dose and trough level. Correlations were adjusted for other SE characteristics.
Among 128 SE episodes, 53 (41%) responded to VPA. Median VPA loading dose was 25.2 mg/kg (range, 7-58 mg/kg). Loading doses and total plasma levels were not associated with the probability of response or mortality. Correcting for other possible confounders (number of previously tried treatment, demographics, SE severity) did not alter these findings. Only 3.8% of SE episodes that responded to VPA received >30 mg/kg.
A high loading dose (>30 mg/kg) is not associated with a greater response rate in patients with SE. Therefore, it seems to bring little benefit. If confirmed in further studies, a dosage of 25-30 mg/kg appears adequate in SE.
Keywords
Administration, Intravenous, Anticonvulsants/therapeutic use, Humans, Retrospective Studies, Status Epilepticus/drug therapy, Valproic Acid/therapeutic use, critical care, efficacy, pharmacokinetics, therapeutic drug monitoring, valproate
Pubmed
Web of science
Funding(s)
Swiss National Science Foundation
Create date
21/06/2022 12:56
Last modification date
25/01/2024 7:38