Carotid-Subclavian Artery Index : Validation of an Echocardiographic Index to Detect Coarctation : P67

Details

Serval ID
serval:BIB_6F4037FD5867
Type
Inproceedings: an article in a conference proceedings.
Publication sub-type
Poster: Summary – with images – on one page of the results of a researche project. The summaries of the poster must be entered in "Abstract" and not "Poster".
Collection
Publications
Institution
Title
Carotid-Subclavian Artery Index : Validation of an Echocardiographic Index to Detect Coarctation : P67
Title of the conference
Annual Conference Swiss Society for Paediatrics
Author(s)
Mivelaz Y., Di Bernardo S., Meijboom E.J., Fall A.L., Sekarski N.
Address
Zürich, Swizterland, June 14-15, 2007
ISBN
1424-7860
Publication state
Published
Issued date
2007
Peer-reviewed
Oui
Volume
137
Series
Swiss Medical Weekly
Pages
31S
Language
english
Abstract
Introduction:
Due to patency of the arterial duct and the parallel circulation during the fetal life, coarctation remains a difficult diagnosis prenatally and even shortly after birth. Fisrtly, our study aimed to assess accuracy of a new cardiographie index based on morphologie measurements of the distal aortic arch, the Carotid-Subclavian Artery Index (CSA Index), the ratio of the distal transverse aortic arch diameter to the distance between the left carotid artery and the left subclavian artery, in detecting coarctation in newborns, infants and children, independently of other cardiac lesions. Secondly, to assess the additive value of another morphologie index in predicting coarctation, the 1/0 ratio, the ratio of isthmus to descending aorta diameter.
Methods:
It is a retrospective cohort study in a tertiary care children's hospital. Offline echocardiographic measurements of great vessels and aortic arch dimensions were done in 69 patients with coarctation. We calculate their CSA index, and their 1/0 ratio. Values of CSA Index and 1/0 ratio from coarctation group were compared with those from a normal local control population. Results: 69 echocardiograms from patients with coarctation were analysed. Compared with controls, patients with coarctation had a significantly lower CSA index (0.88 ±0.49 vs 2.65 ±0.82, p <0.0001) and 1/0 ratio. The same significant difference was observed, independently of age and other associated defects, even complex ones. CSA Index confirmed its good sensitivity and specificity (99% and 96% respectively). This was not improved by adding the I/D ratio.
Conclusions:
An abnormal CSA index is highly suggestive of coarctation independently of age, of the presence of a patent ductus arteriosus or of other cardiac defects. The addition of another anatomie index, the I/D ratio, was not helpful in our study.