Extrafascial injection for interscalene brachial plexus block reduces respiratory complications compared with a conventional intrafascial injection: a randomized, controlled, double-blind trial?.

Details

Serval ID
serval:BIB_5CE9E9371946
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Extrafascial injection for interscalene brachial plexus block reduces respiratory complications compared with a conventional intrafascial injection: a randomized, controlled, double-blind trial?.
Journal
British Journal of Anaesthesia
Author(s)
Palhais N., Brull R., Kern C., Jacot-Guillarmod A., Charmoy A., Farron A., Albrecht E.
ISSN
1471-6771 (Electronic)
ISSN-L
0007-0912
Publication state
Published
Issued date
2016
Peer-reviewed
Oui
Volume
116
Number
4
Pages
531-537
Language
english
Notes
Publication types: Journal Article Publication Status: ppublish
Abstract
BACKGROUND: Hemidiaphragmatic paresis after ultrasound-guided interscalene brachial plexus block is reported to occur in up to 100% of patients. We tested the hypothesis that an injection lateral to the brachial plexus sheath reduces the incidence of hemidiaphragmatic paresis compared with a conventional intrafascial injection, while providing similar analgesia.
METHODS: Forty ASA I-III patients undergoing elective shoulder and clavicle surgery under general anaesthesia were randomized to receive an ultrasound-guided interscalene brachial plexus block for analgesia, using 20 ml bupivacaine 0.5% with epinephrine 1:200 000 injected either between C5 and C6 within the interscalene groove (conventional intrafascial injection), or 4 mm lateral to the brachial plexus sheath (extrafascial injection). The primary outcome was incidence of hemidiaphragmatic paresis (diaphragmatic excursion reduction >75%), measured by M-mode ultrasonography, before and 30 min after the procedure. Secondary outcomes were forced vital capacity, forced expiratory volume in 1 s, and peak expiratory flow. Additional outcomes included time to first opioid request and pain scores at 24 h postoperatively (numeric rating scale, 0-10).
RESULTS: The incidences of hemidiaphragmatic paresis were 90% (95% CI: 68-99%) and 21% (95% CI: 6-46%) in the conventional and extrafascial injection groups, respectively (P<0.0001). Other respiratory outcomes were significantly better preserved in the extrafascial injection group. The mean time to first opioid request was similar between groups (conventional: 802 min [95% CI: 620-984 min]; extrafascial: 973 min [95% CI: 791-1155 min]; P=0.19) as were pain scores at 24 h postoperatively (conventional: 1.6 [95% CI: 0.9-2.2]; extrafascial: 1.6 [95% CI: 0.8-2.4]; P=0.97).
CONCLUSIONS: Ultrasound-guided interscalene brachial plexus block with an extrafascial injection reduces the incidence of hemidiaphragmatic paresis and impact on respiratory function while providing similar analgesia, when compared with a conventional injection.
CLINICAL TRIAL REGISTRATION: NCT02074397.