Automatic adjustment of noninvasive pressure support with a bilevel home ventilator in patients with acute respiratory failure: a feasibility study.

Details

Serval ID
serval:BIB_4311C3F07984
Type
Article: article from journal or magazin.
Collection
Publications
Title
Automatic adjustment of noninvasive pressure support with a bilevel home ventilator in patients with acute respiratory failure: a feasibility study.
Journal
Intensive Care Medicine
Author(s)
Battisti A., Tassaux D., Bassin D., Jolliet P.
ISSN
0342-4642 (Print)
ISSN-L
0342-4642
Publication state
Published
Issued date
2007
Peer-reviewed
Oui
Volume
33
Number
4
Pages
632-638
Language
english
Notes
Publication types: Journal ArticlePublication Status: ppublish
Abstract
OBJECTIVE: To test the feasibility of applying noninvasive ventilation (NIV) using a prototype algorithm implemented in a bilevel ventilation device designed to adjust pressure support (PS) to maintain a clinician-set alveolar ventilation in patients with acute respiratory failure after initial stabilization.
DESIGN AND SETTING: Prospective crossover interventional study in an intensive care unit, university hospital.
PATIENTS: 19 patients receiving NIV for acute hypercapnic respiratory failure (13 men, 6 women; mean age 70+/-11 years).
METHODS: The same bilevel ventilator was used with manually adjusted PS and with the automated algorithm (autoPS), set to maintain the same alveolar ventilation as in PS. Sequence (measurements at end of each period): (a) prior to initiating NIV (baseline 1); (b) 45 min with manually set PS; (c) 60 min without NIV; (d) 45 min with autoPS; (e) 60 min without NIV; (f) 45 min with manually set PS.
RESULTS: The magnitude of decrease in PaCO(2) and increase in pH with autoPS was comparable to that of conventional PS, with the same alveolar ventilation and level of PS. No technical problem occurred in autoPS mode, and no NIV trial had to be discontinued because of patient discomfort.
CONCLUSIONS: These results suggest that the alveolar ventilation based automatic control of PS during NIV with a bilevel device is feasible and leads to beneficial effects in patients with acute respiratory failure comparable to those of manually set PS. Further studies should now explore the potential of this system over longer periods in patients with acute and chronic respiratory failure.
Keywords
Aged, Aged, 80 and over, Automation, Blood Pressure, Cross-Over Studies, Feasibility Studies, Female, Heart Rate, Humans, Intervention Studies, Male, Middle Aged, Positive-Pressure Respiration, Respiration, Artificial/methods, Respiratory Distress Syndrome, Adult/therapy
Pubmed
Web of science
Create date
27/06/2013 15:12
Last modification date
20/08/2019 14:46
Usage data