Refractive outcomes and complications after combined copolymer phakic intraocular lens explantation and phacoemulsification with intraocular lens implantation.

Details

Serval ID
serval:BIB_3B86A7D9BC77
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Refractive outcomes and complications after combined copolymer phakic intraocular lens explantation and phacoemulsification with intraocular lens implantation.
Journal
Journal of cataract and refractive surgery
Author(s)
Meier P.G., Majo F., Othenin-Girard P., Bergin C., Guber I.
ISSN
1873-4502 (Electronic)
ISSN-L
0886-3350
Publication state
Published
Issued date
06/2017
Peer-reviewed
Oui
Volume
43
Number
6
Pages
748-753
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
To assess safety, efficacy, and predictability of combined Implantable Collamer Lens phakic intraocular lens (pIOL) explantation and phacoemulsification and to report the rate of complications. A secondary aim was to examine whether intraocular lens (IOL) power calculation was affected by the pIOL in situ.
Jules-Gonin Eye Hospital, Lausanne, Switzerland.
Retrospective case series.
The records of patients having pIOL implantation with subsequent phacoemulsification were reviewed. Data analysis was performed between July 1, 2015, and December 31, 2015. The mean corrected distance visual acuity (CDVA), safety, stability of refraction, predictability of IOL power calculation, and postoperative complications were recorded.
The study comprised 38 eyes (29 patients). Of the eyes, 32 (82%) were within ±1.00 diopter (D) of the target refraction and 21 (57.9%) were within ±0.50 D. The mean CDVA after IOL implantation was significantly better than before pIOL implantation (P < .001) and similar to after pIOL implantation (P = .87). The safety of this multistepped procedure was good; on average, 1.6 Snellen lines of CDVA were gained over before pIOL implantation. Branch retinal vein occlusion occurred in 1 eye; no other sight-threatening complications were observed. Posterior capsule opacification developed in 15 eyes (39.5%) and was treated successfully with neodymium:YAG capsulotomy.
The highest mean CDVA was recorded at the final visit. Good safety, stability, and predictability were also observed. Postoperative complications were few and in all but 1 case, not sight threatening. Overall, results indicate the combination of procedures does not negatively affect the final visual outcome.
Keywords
Cataract Extraction, Device Removal, Humans, Lens Implantation, Intraocular/methods, Phacoemulsification, Phakic Intraocular Lenses, Polymers, Postoperative Complications, Retrospective Studies, Visual Acuity