Simultaneous Evaluation of Bone Cut and Implant Placement Accuracy in Robotic-Assisted Total Knee Arthroplasty.

Details

Ressource 1Download: jcm-13-01293.pdf (3414.53 [Ko])
State: Public
Version: Final published version
License: CC BY 4.0
Serval ID
serval:BIB_3AB4D8CB4BDD
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Simultaneous Evaluation of Bone Cut and Implant Placement Accuracy in Robotic-Assisted Total Knee Arthroplasty.
Journal
Journal of clinical medicine
Author(s)
Cosendey K., Stanovici J., Cadas H., Omoumi P., Jolles B.M., Favre J.
ISSN
2077-0383 (Print)
ISSN-L
2077-0383
Publication state
Published
Issued date
25/02/2024
Peer-reviewed
Oui
Volume
13
Number
5
Pages
1293
Language
english
Notes
Publication types: Journal Article
Publication Status: epublish
Abstract
Background: This study aimed to evaluate the accuracy of bone cuts and implant placements, simultaneously, for total knee arthroplasty (TKA) performed using a system with an active robotic arm. Methods: Two experienced orthopaedic surgeons performed TKA on ten cadaveric legs. Computed tomography scans were performed to compare the bone cuts and implant placements with the preoperative planning. The differences between the planned and actual bone cuts and implant placements were assessed using positional and angular errors in the three anatomical planes. Additionally, the cut-implant deviations were calculated. Statistical analysis was performed to detect systematic errors in the bone cuts and implant placements and to quantify the correlations between these errors. Results: The root-mean-square (RMS) errors of the bone cuts (with respect to the planning) were between 0.7-1.5 mm and 0.6-1.7°. The RMS implant placement errors (with respect to the planning) varied between 0.6-1.6 mm and 0.4-1.5°, except for the femur and tibia in the sagittal plane (2.9°). Systematic errors in the bone cuts and implant placements were observed, respectively, in three and two degrees of freedom. For cut-implant deviations, the RMS values ranged between 0.3-2.0 mm and 0.6-1.9°. The bone cut and implant placement errors were significantly correlated in eight degrees-of-freedom (ρ ≥ 0.67, p < 0.05). Conclusions: With most of the errors below 2 mm or 2°, this study supported the value of active robotic TKA in achieving accurate bone cuts and implant placements. The findings also highlighted the need for both accurate bone cuts and proper implantation technique to achieve accurate implant placements.
Keywords
General Medicine, accuracy, bone cuts and implant placements, position and orientation errors, robotic-assisted surgery, total knee arthroplasty
Pubmed
Web of science
Open Access
Yes
Create date
25/03/2024 16:17
Last modification date
12/04/2024 7:45
Usage data