The non-circular shape of FloWatch-PAB prevents the need for pulmonary artery reconstruction after banding. Computational fluid dynamics and clinical correlations

Details

Ressource 1Download: REF.pdf (329.27 [Ko])
State: Public
Version: Final published version
License: Not specified
It was possible to publish this article open access thanks to a Swiss National Licence with the publisher.
Serval ID
serval:BIB_26E9F0216286
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
The non-circular shape of FloWatch-PAB prevents the need for pulmonary artery reconstruction after banding. Computational fluid dynamics and clinical correlations
Journal
European Journal of Cardio-Thoracic Surgery
Author(s)
Corno  A. F., Prosi  M., Fridez  P., Zunino  P., Quarteroni  A., von Segesser  L. K.
ISSN
1010-7940
Publication state
Published
Issued date
01/2006
Peer-reviewed
Oui
Volume
29
Number
1
Pages
93-9
Notes
Journal Article --- Old month value: Jan
Abstract
OBJECTIVE: To evaluate the differences between non-circular shape of FloWatch-PAB and conventional pulmonary artery (PA) banding. METHODS: Geometrical analysis. Conventional banding and FloWatch-PAB perimeters were plotted against cross-sections. Computational fluid dynamics (CFD) model. CFD compared non-circular FloWatch-PAB cross-sections with conventional banding regarding pressure gradients. Clinical data. Seven children, median age 2 months (7 days to 3 years), median weight 4.2 kg (3.2-9.8 kg), with complex congenital heart defects underwent PA banding with FloWatch-PAB implantation. RESULTS: Geometrical analysis. Conventional banding: progressive reduction of cross-sections was accompanied by progressive reduction of PA perimeters. FloWatch-PAB: with equal reduction of cross-sections the PA perimeter remained constant. CFD model. Non-circular and circular banding provided same trans-banding pressure gradients for same cross-sections at any given flow. Clinical data. Mean PA internal diameter at banding was 13.3+/-4.5 mm. After a mean interval of 5.9+/-3.7 months, all children underwent intra-cardiac repair and simple FloWatch-PAB removal without PA reconstruction. Mean PA internal diameter with FloWatch-PAB removal increased from 3.0+/-0.8 to 12.4+/-4.5 mm (normal mean internal diameter for the age=9.9+/-1.6). No residual pressure gradient was recorded in correspondence of the site of the previous FloWatch-PAB implantation in 6/7 patients, 10 mmHg peak and 5 mmHg mean gradient in 1/7. CONCLUSIONS: The non-circular shape of FloWatch-PAB can replace conventional circular banding with the following advantages: (a) the pressure gradient will remain essentially the same as for conventional circular banding for any given cross-section, but with significantly smaller reduction of PA perimeter; and (b) PA reconstruction at the time of de-banding for intra-cardiac repair can be avoided.
Keywords
*Blood Vessel Prosthesis Cardiac Surgical Procedures/instrumentation Child, Preschool Computer Simulation Coronary Circulation/physiology Echocardiography, Doppler, Color/methods Echocardiography, Transesophageal/methods Heart Defects, Congenital/physiopathology/*surgery Humans Infant Infant, Newborn Models, Cardiovascular Prosthesis Design Pulmonary Artery/physiopathology/*surgery
Pubmed
Web of science
Open Access
Yes
Create date
14/02/2008 15:18
Last modification date
14/02/2022 8:54
Usage data