In vivo application of intestinal pH measurement using 2',7'-bis(carboxyethyl)-5,6-carboxyfluorescein (BCECF) fluorescence imaging

Details

Serval ID
serval:BIB_22CCA27C71B4
Type
Article: article from journal or magazin.
Collection
Publications
Title
In vivo application of intestinal pH measurement using 2',7'-bis(carboxyethyl)-5,6-carboxyfluorescein (BCECF) fluorescence imaging
Journal
Photochem Photobiol
Author(s)
Marechal X., Mordon S., Devoisselle J. M., Begu S., Guery B., Neviere R., Buys B., Dhelin G., Lesage J. C., Mathieu D., Chopin C.
ISSN
0031-8655 (Print)
ISSN-L
0031-8655
Publication state
Published
Issued date
11/1999
Volume
70
Number
5
Pages
813-9
Language
english
Notes
Marechal, X
Mordon, S
Devoisselle, J M
Begu, S
Guery, B
Neviere, R
Buys, B
Dhelin, G
Lesage, J C
Mathieu, D
Chopin, C
eng
Research Support, Non-U.S. Gov't
Photochem Photobiol. 1999 Nov;70(5):813-9.
Abstract
Measurement of gastrointestinal intramucosal pH (pHim) has been recognized as an important factor in the detection of hypoxia-induced dysfunctions. However, current pH measurement techniques are limited in terms of time and spatial resolutions. A major advance in accurate pH measurement was the development of the ratiometric fluorescent indicator dye, 2',7'-bis(carboxyethyl)-5,6-carboxyfluorescein (BCECF). This study aimed to set up and validate a fluorescence imaging technique to measure in vivo the intramucosal pH (pHim) of the intestine. The intestine was inserted into an optical chamber placed under a microscope. Animals were injected intravenously with the pH-sensitive fluorescent dye BCECF. Fluorescence was visualized by illuminating the intestine alternately at 490 and 470 nm. The emitted fluorescence was directed to an intensified camera. The ratio of emitted fluorescence at excitation wavelengths of 490 and 470 nm was measured, corrected and converted to pHim by constructing a calibration curve. The pHim controls were performed with a pH microelectrode and were correlated with venous blood gas sampling. Results show that pHim is determined with an accuracy of +/- 0.07 pH units and a response time of 1 min. In conclusion pHim mapping of rat intestine can be obtained by fluorescence imaging using BCECF. This technology could be easily adapted for endoscopic pH measurements.
Keywords
Animals, *Fluoresceins/pharmacokinetics, *Fluorescent Dyes/pharmacokinetics, Hydrogen-Ion Concentration, Intestinal Mucosa/*metabolism, Male, Microscopy, Fluorescence/instrumentation, Rats, Rats, Sprague-Dawley