A Simplified Fluoroscopic Method for Commissural Alignment Assessment With a Balloon-Expandable Transcatheter Heart Valve.

Details

Ressource 1Download: main.pdf (817.42 [Ko])
State: Public
Version: Final published version
License: CC BY-NC-ND 4.0
Serval ID
serval:BIB_1F779B40DC42
Type
Article: article from journal or magazin.
Collection
Publications
Title
A Simplified Fluoroscopic Method for Commissural Alignment Assessment With a Balloon-Expandable Transcatheter Heart Valve.
Journal
JACC. Case reports
Author(s)
Akodad M., Meier D., Tzimas G., Leipsic J., Blanke P., Wood D.A., Webb J.G., Sathananthan J.
ISSN
2666-0849 (Electronic)
ISSN-L
2666-0849
Publication state
Published
Issued date
03/05/2023
Peer-reviewed
Oui
Volume
13
Pages
101804
Language
english
Notes
Publication types: Case Reports ; Journal Article
Publication Status: epublish
Abstract
We sought to assess commissural alignment of the balloon-expandable valve on fluoroscopy. Commissural alignment was defined on fluoroscopy in 20 patients according to alignment of the valve commissural posts in the 3-cusp and the cusp-overlap view and correlated with post-transcatheter aortic valve replacement computed tomography. Agreement was strong between computed tomography and fluoroscopy (weighted Cohen's kappa coefficient: 0.88). (Level of Difficulty: Advanced.).
Keywords
aortic valve, computed tomography, valve replacement
Pubmed
Open Access
Yes
Create date
17/01/2025 21:11
Last modification date
18/01/2025 7:08
Usage data