Consistency and reproducibility of next-generation sequencing in cytopathology: A second worldwide ring trial study on improved cytological molecular reference specimens.

Details

Serval ID
serval:BIB_0DE727B0F676
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Consistency and reproducibility of next-generation sequencing in cytopathology: A second worldwide ring trial study on improved cytological molecular reference specimens.
Journal
Cancer cytopathology
Author(s)
Pisapia P., Malapelle U., Roma G., Saddar S., Zheng Q., Pepe F., Bruzzese D., Vigliar E., Bellevicine C., Luthra R., Nikiforov Y.E., Mayo-de-Las-Casas C., Molina-Vila M.A., Rosell R., Bihl M., Savic S., Bubendorf L., de Biase D., Tallini G., Hwang D.H., Sholl L.M., Vander Borght S., Weynand B., Stieber D., Vielh P., Rappa A., Barberis M., Fassan M., Rugge M., De Andrea C.E., Lozano M.D., Lupi C., Fontanini G., Schmitt F., Dumur C.I., Bisig B., Bongiovanni M., Merkelbach-Bruse S., Büttner R., Nikiforova M.N., Roy-Chowdhuri S., Troncone G.
Working group(s)
Molecular Cytopathology Meeting Group
ISSN
1934-6638 (Electronic)
ISSN-L
1934-662X
Publication state
Published
Issued date
05/2019
Peer-reviewed
Oui
Volume
127
Number
5
Pages
285-296
Language
english
Notes
Publication types: Journal Article
Publication Status: ppublish
Abstract
Artificial genomic reference standards in a cytocentrifuge/cytospin format with well-annotated genomic data are useful for validating next-generation sequencing (NGS) on routine cytopreparations. Here, reference standards were optimized to be stained by different laboratories before DNA extraction and to contain a lower number of cells (2 × 10 <sup>5</sup> ). This was done to better reflect the clinical challenge of working with insufficient cytological material.
A total of 17 worldwide laboratories analyzed customized reference standard slides (slides A-D). Each laboratory applied its standard workflow. The sample slides were engineered to harbor epidermal growth factor receptor (EGFR) c.2235_2249del15 p.E746_A750delELREA, EGFR c.2369C>T p.T790M, Kirsten rat sarcoma viral oncogene homolog (KRAS) c.38G>A p.G13D, and B-Raf proto-oncogene, serine/threonine kinase (BRAF) c.1798_1799GT>AA p.V600K mutations at various allele frequencies (AFs).
EGFR and KRAS mutation detection showed excellent interlaboratory reproducibility, especially on slides A and B (10% and 5% AFs). On slide C (1% AF), either the EGFR mutation or the KRAS mutation was undetected by 10 of the 17 laboratories (58.82%). A reassessment of the raw data in a second-look analysis highlighted the mutations (n = 10) that had been missed in the first-look analysis. BRAF c.1798_1799GT>AA p.V600K showed a lower concordance rate for mutation detection and AF quantification.
The data show that the detection of low-abundance mutations is still clinically challenging and may require a visual inspection of sequencing reads to detect. Genomic reference standards in a cytocentrifuge/cytospin format are a valid tool for regular quality assessment of laboratories performing molecular studies on cytology with low-AF mutations.
Keywords
Biomarkers, Tumor/genetics, Cytodiagnosis/methods, DNA Mutational Analysis/methods, ErbB Receptors/genetics, High-Throughput Nucleotide Sequencing/methods, Humans, Mutation, Neoplasms/diagnosis, Neoplasms/genetics, Proto-Oncogene Proteins B-raf/genetics, Proto-Oncogene Proteins p21(ras)/genetics, Reproducibility of Results, cytological molecular reference, cytology, lung cancer, molecular cytopathology, next-generation sequencing
Pubmed
Web of science
Create date
30/04/2019 15:19
Last modification date
27/04/2020 5:20
Usage data