Mesure de l'effet d'un bronchodilatateur. [Measurement of the effect of a bronchodilator agent]

Details

Serval ID
serval:BIB_04F7AF1CF117
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Mesure de l'effet d'un bronchodilatateur. [Measurement of the effect of a bronchodilator agent]
Journal
Schweizerische Rundschau fur Medizin Praxis
Author(s)
Fitting  J. W.
ISSN
1013-2058 (Print)
Publication state
Published
Issued date
05/1990
Volume
79
Number
22
Pages
688-90
Notes
English Abstract
Journal Article --- Old month value: May 29
Abstract
Response in a bronchodilator must be expressed by the combining the largest amplitude of response with the highest reproducibility. The forced expiratory volume in the first second (FEV1) meets these conditions and thus represents the best test. The bronchodilator response is commonly expressed in percent of the initial FEV1. Through a mathematical bias, this method overestimates the response in the most severely obstructed subjects. Expressing the bronchodilator response in percent of predicted FEV1 eliminates this distortion and must be preferred.
Keywords
Airway Obstruction/drug therapy Bronchi/*drug effects Bronchodilator Agents/*pharmacology/therapeutic use *Forced Expiratory Volume/drug effects Humans Maximal Expiratory Flow Rate/drug effects